Friday, November 20, 2026

Going off the grid - incrementally

Readers of my blog and web site know that I have installed a LOT (46 to date!) of solar panels over the years.  But they are all grid tied - meaning that when the grid goes down, my panels stop producing power to protect the back feed from harming line workers.  This is how grid solar works.  My backup is a whole home automatic standby generator that runs on propane.

People often assume I have a battery - but big whole house battery systems can cost well over $30,000!  But over the years battery generators have improved from simple camping devices to really large units that can produce 240V at 7200W at 5120Watt Hours.   

Pecron F5000LFP

In my research I found that Pecron makes the most affordable high capacity battery generator on the market as of November 2026.  At a little over $2000 their F5000LFP model is an amazing buy - significantly less expensive than competing brands and rich with features and accessories.  So I jumped in.  

Reliance 10 circuit transfer switch kit 

Since this unit can produce 240V - I can set it up to power most of the loads in my home.  But the first step is to install a transfer switch that will allow me to select which circuits I want to run from the generator.  The biggest essential load is my 1500W well pump, followed by the on demand water heater, fridge and propane heaters - plus all the kitchen outlets and most of the lights.  I found a really good deal on an open box unit on eBay and spent a day or so installing it.

 
Here I have opened up the main breaker panel and I have all the parts ready to install.
I cut a hole in the drywall and mounted the transfer switch. Then in order to get all the wires to feed into the breaker box, I had to cut through a few studs to feed the big 1" conduit over to the breakers.  (You can see the cutout in the drywall).
 

This particular kit did not have all the wires labelled, so I had to meticulously test all the wires to find the pairs that connect to each circuit.  I labelled each pair carefully, then proceeded to connect them all inside the main breaker.  I had to turn off the main power for safety, and used my Ecoflow Delta 2 battery generator to power a flood light while I worked in this dark corner of my basement.

Labelled switches
Here is the transfer switch all wired up and labelled.  Each switch can select LINE-OFF-GENERATOR and they have a circuit breaker for each generator circuit.  The bottom double switch is for my 240V 1500W well pump.  The big socket on the bottom right is where the generator plugs in.  And 2 small meters show the total load on each half of the 240V feed.

Labelled breakers
I used my Niimbot D110 labeller for all this to make it all clean and readable.

Then I had to wait a week or so for the Pecron generator to arrive by truck freight.  It came on a pallet with a combined weight of 160lbs!  The actual generator weighs about 120lbs.  I'm glad they provided a base with casters!

Ground mounted solar arrays

Last year I had installed 2 ground mounted solar arrays that are "plug-in" arrays.  The 4 panels on the left produce about 800W and feed power to a 1kW inverter.  The 4 larger 440W panels produce about 1800W and connect to a 2kW inverter that plugs in to a 240V outlet just below my main breaker. 

2kW and 1kW plug-in inverters
Now I needed a way to switch the solar power between these inverters and the generator inputs so I can charge it.

DC solar circuit breakers

I added 2 more high power DC circuit breakers that allow me to switch power to either or both systems.  Eventually I may just remove these inverters and use them exclusively to power the Pecron generator, but for now I like having options.  Essentially this switches the solar panels from grid tied inverters to the off-grid Pecron battery generator.

complete system

So finally I was able to hook the Pecron to the transfer switch with the BIG black cable (30Amp rated!) that came with the transfer switch.  And right away I was charging the Pecron from solar while also powering my house off the grid!

app screenshot

I installed the Pecron app on my phone and connected it via bluetooth and wi-fi so I can now monitor the system from anywhere.  It was late in the day when I took this screenshot, so the solar was only producing 20W and my house was just running a base load of lights etc.  But when I ran water long enough to trigger the well pump it ran just fine.  At 1500W that load is well within the 7kW capacity of the Pecron.

The next day my solar panels had fully charged the Pecron in just a few hours and I was running all the loads.  But in the evening I switched heavy loads like the fridge back to grid power because the 5kWh capacity of the Pecron might not be enough to last the whole night.  So I will be transferring that circuit to solar in the morning and grid at night.  

PECRON FP5000-48V 5120Wh

Eventually I plan to buy an add-on battery - the Pecron can handle up to 6 add-on units.  Each battery adds 5120kWh and costs about $1200 - so I'm not in a hurry to get one.  But adding one would definitely allow me to run my home 24/7 on the Pecron system assuming I have enough sun for my solar arrays.

Pecron with 6 batteries stacked

Currently in a power outage my automatic propane standby generator kicks in to power my whole property.  That generator has over 1000 hours on it and is becoming expensive to maintain, so eventually adding batteries my become cheaper than replacing it.  Plus I would no longer need to use fossil fuel as my backup system.  I'm going off the grid incrementally!

But it will be interesting when I do get an outage because the house will be off-grid and I may not notice the transition.  My propane generator will then just be running my workshop building and the only thing I really need to use during an outage is my desktop computer in my office.  So I can use my Ecoflow Delta 2 battery generator to power that for many hours as needed and I can just shut off the propane generator.

I also have a few UPS units to back up my TV/AV system and my 3D printers and can use those as needed.  I currently need these to fill in the 15 second gap between a power failure and when the propane generator kicks in.

It will be an ongoing adventure as I increment to being fully off-grid!
 